The WIN72 unit is useful to determine the residual volumetric expansion of the cylinder under test pressure control
Maximum service pressure: 500 bar. The WIN72 unit is useful to determine the residual volumetric expansion of the cylinder under test pressure control. The unit is composed by a painted steel cabinet. In it, you can find the hydraulic test pump and the hydraulic circuit. On the top surface of the cabinet, the control valves and optionally the pressure recorder are installed. An expansion checking device by means of electronic weight method – 0,1 grams accuracy; A water jacket containing the cylinder during the test.
Download
WINJ72 model – Cylinder hydraulic expansion test control unit
The equipment is designed for the hydraulic testing of high pressure cylinders and fire extinguishers.
El-60-e Electric Valving for a small cylander
System designed to internally treat the cylinders /reservoirs with a series of purge and vacuum cycles.
The FIT-6-EVO-DUO is a fully automated pressure testing ramp for 6+6 gas cylinders. It is good for ONLY 25E thread. Water filling, pressure testing, emptying is happened through one simple connection. Maximum pressure is 450 bar. Gas cylinbder diameter 110-270 mm Gas cylinder length 500-1755 mm Capacity minimum 30 gas cylinder/hour with 1 operator.